To: Users From: Bob Supnik Subj: HP2100 Simulator Usage Date: 20-Aug-2004 COPYRIGHT NOTICE The following copyright notice applies to both the SIMH source and binary: Original code published in 1993-2004, written by Robert M Supnik Copyright (c) 1993-2004, Robert M Supnik Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files (the "Software"), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge, publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is furnished to do so, subject to the following conditions: The above copyright notice and this permission notice shall be included in all copies or substantial portions of the Software. THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL ROBERT M SUPNIK BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE. Except as contained in this notice, the name of Robert M Supnik shall not be used in advertising or otherwise to promote the sale, use or other dealings in this Software without prior written authorization from Robert M Supnik. This memorandum documents the HP 2100 simulator. 1. Simulator Files sim/ scp.h sim_console.h sim_defs.h sim_fio.h sim_rev.h sim_sock.h sim_tape.h sim_timer.h sim_tmxr.h scp.c sim_console.c sim_fio.c sim_sock.c sim_tape.c sim_timer.c sim_tmxr.c sim/hp2100/ hp2100_defs.h hp2100_cpu.c hp2100_fp.c hp2100_dp.c hp2100_dq.c hp2100_dr.c hp2100_ipl.c hp2100_lps.c hp2100_lpt.c hp2100_mt.c hp2100_ms.c hp2100_mux.c hp2100_stddev.c hp2100_sys.c 2. HP2100 Features The HP2100 simulator is configured as follows: device simulates name(s) CPU 2116 CPU with 32KW memory 2100 CPU with 32KW memory, FP or IOP instructions 21MX CPU with 1024KW memory, FP or DMS instructions DMA0, DMA1 dual channel DMA controller PTR,PTP 12597A paper tape reader/punch TTY 12531C buffered terminal controller LPS 12653A printer controller with 2767 printer 12566B microcircuit interface for diagnostics LPT 12845A printer controller with 2607 printer CLK 12539A/B/C time base generator MUXL,MUXU,MUXC 12920A terminal multiplexor DP 12557A disk controller with four 2871 drives 13210A disk controller with four 7900 drives DQ 12565A disk controller with two 2883 drives DR 12606B fixed head disk controller with 2770/2771 disks 12610B drum controller with 2773/2774/2775 drums MT 12559C magnetic tape controller with one 3030 drive MS 13181A magnetic tape controller with four 7970B drives 13183A magnetic tape controller with four 7970E drives IPLI 12556B interprocessor link, input side IPLO 12556B interprocessor link, output side The HP2100 simulator implements several unique stop conditions: - decode of an undefined instruction, and STOP_INST is set - reference to an undefined I/O device, and STOP_DEV is set - more than INDMAX indirect references are detected during memory reference address decoding The HP2100 loader supports standard absolute binary format. The DUMP command is not implemented. 2.1 CPU CPU options include choice of instruction set and memory size. SET CPU 2116 2116 CPU SET CPU 2100 2100 CPU SET CPU 21MX 21MX CPU SET CPU EAU EAU instructions (2116 only) SET CPU NOEAU no EAU instructions (2116 only) SET CPU FP FP instructions (2100 only) SET CPU NOFP no FP instructions (2100 only) SET CPU IOP IOP instructions (2100, 21MX only) SET CPU NOIOP no IOP instructions (2100, 21MX only) SET CPU DMS DMS instructions (21MX only) SET CPU NODMS no DMS instructions (21MX only) SET CPU 4K set memory size = 4K SET CPU 8K set memory size = 8K SET CPU 16K set memory size = 16K SET CPU 32K set memory size = 32K SET CPU 64K set memory size = 64K (21MX only) SET CPU 128K set memory size = 128K (21MX only) SET CPU 256K set memory size = 256K (21MX only) SET CPU 512K set memory size = 512K (21MX only) SET CPU 1024K set memory size = 1024K (21MX only) On the 2100, EAU is standard, and the FP and IOP options are mutually exclusive. On the 21MX, EAU and FP are standard. The 2100 and 21MX include memory protection as standard; the 21MX optionally includes DMS (dynamic memory system). If memory size is being reduced, and the memory being truncated contains non-zero data, the simulator asks for confirmation. Data in the truncated portion of memory is lost. Initial memory size is 32K. These switches are recognized when examining or depositing in CPU memory: -v if DMS enabled, interpret address as virtual -s if DMS enabled, force system map -u if DMS enabled, force user map -p if DMS enabled, force port A map -q if DMS enabled, force port B map The CPU implements four different kinds of instruction breakpoints: -e break unconditionally -n break if DMS is disabled -s break if DMS enabled and system map -u break if DMS enabled and user map CPU registers include the visible state of the processor as well as the control registers for the interrupt system. name models size comments P all 15 program counter A all 16 A register B all 16 B register M all 15 M (memory address) register T all 16 T (memory data) register X 21MX 16 X index register Y 21MX 16 Y index register S all 16 switch/display register E all 1 extend flag O all 1 overflow flag ION all 1 interrupt enable flag ION_DEFER all 1 interrupt defer flag CIR all 6 current interrupt register MPCTL 2100,21MX 1 memory protection enable MPFLG 2100,21MX 1 memory protection flag MPFBF 2100,21MX 1 memory protection flag buffer MPFR 2100,21MX 15 memory protection fence MPVR 2100,21MX 16 memory protection violation reg MPEVR 2100,21MX 1 memory protection freeze flag MPMEV 2100,21MX 1 memory protection DMS error flag DMSENB 21MX 1 DMS enable DMSCUR 21MX 1 DMS current mode DMSSR 21MX 16 DMS status register DMSVR 21MX 16 DMS violation register DMSMAP[128] 21MX 16 DMS maps [0:31] system map [32:63] user map [64:95] port A map [96:127] port B map STOP_INST all 1 stop on undefined instruction STOP_DEV all 1 stop on undefined device INDMAX all 16 indirect address limit PCQ[0:63] all 15 P of last JMP, JSB, or interrupt; most recent P change first WRU all 8 interrupt character BOOT CPU implements the 21MX IBL facility. IBL is controlled by the switch register S. S<15:14> selects the device to boot: 00 paper-tape reader (12992K ROM) 01 7900A/2883 disk (12992A ROM) 10 7970B/E tape (12992D ROM) 11 undefined For the 7900A/2883 only, S<13:12> specify the type of disk: 00 7900A 10 2883 S<11:6> contains the device address. If the device has two addresses, S<11:6> specifies the lower address. S<5:3> are passed to the bootstrap program. S<2:0> specify options for the boot loader. IBL will not report an error if the device address in S<11:6> is incorrect. 2.2 DMA Controllers The HP2100 includes two DMA channel controllers (DMA0 and DMA1). Each DMA channel has the following visible state: name size comments CMD 1 channel enabled CTL 1 interrupt enabled FLG 1 channel ready FBF 1 channel ready buffer CW1 16 command word 1 CW2 16 command word 2 CW3 16 command word 3 2.3 Variable Device Assignments On the HP2100, I/O device take their device numbers from the backplane slot they are plugged into. Thus, device number assignments vary considerably from system to system, and software package to software package. The HP2100 simulator supports dynamic device number assignment. To show the current device number, use the SHOW DEVNO command: sim> SHOW PTR DEV device=10 To change the device number, use the SET DEVNO= command: sim> SET PTR DEV=30 sim> SHOW PTR DEV device=30 The new device number must be in the range 010..077 (octal). For devices with two device numbers, only the lower numbered device number can be changed; the higher is automatically set to the lower + 1. If a device number conflict occurs, the simulator will return an error when started. In addition, most devices can be enabled or disabled. To enable a device, use the SET ENABLED command: sim> SET DPC ENABLED To disable a device, use the SET DISABLED command: sim> SET DPC DISABLED For devices with more than one device number, disabling or enabling any device in the set disables all the devices. 2.4 Programmed I/O Devices 2.4.1 12597A-002 Paper Tape Reader (PTR) The paper tape reader (PTR) reads data from a disk file. The POS register specifies the number of the next data item to be read. Thus, by changing POS, the user can backspace or advance the reader. The paper tape reader supports the BOOT command. BOOT PTR copies the IBL into memory and starts it running. The switch register (S) is set automatically to the value expected by the IBL loader: <15:12> = 0000 <11:6> = device code <5:3> = unchanged <2:0> = 000 The paper tape reader implements these registers: name size comments BUF 8 last data item processed CMD 1 reader enable CTL 1 device/interrupt enable FLG 1 device ready FBF 1 device ready buffer SRQ 1 device DMA service request TRLLIM 8 number of trailing nulls to append after end-of-file is detected POS 32 position in the input file TIME 24 time from I/O initiation to interrupt STOP_IOE 1 stop on I/O error Error handling is as follows: error STOP_IOE processed as not attached 1 report error and stop 0 out of tape end of file 1 report error and stop 0 out of tape or paper OS I/O error x report error and stop 2.4.2 12597A-005 Paper Tape Punch (PTP) The paper tape punch (PTP) writes data to a disk file. The POS register specifies the number of the next data item to be written. Thus, by changing POS, the user can backspace or advance the punch. The paper tape punch implements these registers: name size comments BUF 8 last data item processed CMD 1 punch enable CTL 1 device/interrupt enable FLG 1 device ready FBF 1 device ready buffer SRQ 1 device DMA service request POS 32 position in the output file TIME 24 time from I/O initiation to interrupt STOP_IOE 1 stop on I/O error Error handling is as follows: error STOP_IOE processed as not attached 1 report error and stop 0 out of tape OS I/O error x report error and stop 2.4.3 12531C Buffered Terminal (TTY) The console terminal has three units: keyboard (unit 0), printer (unit 1), and punch (unit 2). The keyboard reads from the console keyboard; the printer writes to the simulator console window. The punch writes to a disk file. The keyboard and printer units (TTY0, TTY1) can be set to one of three modes: UC, 7B, or 8B. In UC mode, lower case input and output characters are automatically converted to upper case. In 7B mode, input and output characters are masked to 7 bits. In 8B mode, characters are not modified. In UC and 7B mode, output of null characters is suppressed; in 8B mode, output of null characters is permitted. Changing the mode of either the keyboard or the printer changes both. The default mode is UC. Some HP software systems expect the console terminal to transmit line-feed automatically following carriage-return. This feature is enabled with: SET TTY AUTOLF and disabled with: SET TTY NOAUTOLF The console teleprinter implements these registers: name size comments BUF 8 last data item processed MODE 16 mode CTL 1 device/interrupt enable FLG 1 device ready FBF 1 device ready buffer SRQ 1 device DMA service request KPOS 32 number of characters input KTIME 24 keyboard polling interval TPOS 32 number of characters printed TTIME 24 time from I/O initiation to interrupt PPOS 32 position in the punch output file STOP_IOE 1 punch stop on I/O error Error handling for the punch is as follows: error STOP_IOE processed as not attached 1 report error and stop 0 out of tape OS I/O error x report error and stop 2.4.4 12653A Printer Controller (LPS) with 2767 Printer 12566B Microcircuit Interface The 12653A line printer uses the 12566B microcircuit interface as its controller. As a line printer, LPS writes data to a disk file. The POS register specifies the number of the next data item to be written. Thus, by changing POS, the user can backspace or advance the printer. As a microcircuit interface, LPS provides the DMA test device for running the dual channel port controller and DMS diagnostics. Printer mode verus diagnostic mode is controlled by the commands: SET LPS PRINTER configure as line printer SET LPS DIAG configure for diagnostic tests The 12653A is disabled by default. The 12653A implements these registers: name size comments BUF 16 output buffer STA 16 input buffer or status CMD 1 printer enable CTL 1 device/interrupt enable FLG 1 device ready FBF 1 device ready buffer SRQ 1 device DMA service request POS 32 position in the output file CTIME 24 time between characters PTIME 24 time for a print operation STOP_IOE 1 stop on I/O error In printer mode, error handling is as follows: error STOP_IOE processed as not attached 1 report error and stop 0 out of tape or paper OS I/O error x report error and stop In diagnostic mode, there are no errors; data sent to the output buffer is looped back to the status register with a fixed delay of 1. 2.4.5 12845A Printer Controller (LPT) The line printer (LPT) writes data to a disk file. The POS register specifies the number of the next data item to be written. Thus, by changing POS, the user can backspace or advance the printer. The line printer implements these registers: name size comments BUF 8 last data item processed CMD 1 printer enable CTL 1 device/interrupt enable FLG 1 device ready FBF 1 device ready buffer SRQ 1 device DMA service request LCNT 7 line count within page POS 32 position in the output file CTIME 24 time between characters PTIME 24 time for a print operation STOP_IOE 1 stop on I/O error Error handling is as follows: error STOP_IOE processed as not attached 1 report error and stop 0 out of tape or paper OS I/O error x report error and stop 2.4.6 12539A/B/C Time Base Generator (CLK) The time base generator (CLK) implements these registers: name size comments SEL 3 time base select CTR 14 repeat counter for < 1Hz operation CTL 1 device/interrupt enable FLG 1 device ready FBF 1 device ready buffer ERR 1 error flag TIME[0:7] 31 clock intervals, select = 0..7 DEVNO 6 current device number (read only) The time base generator autocalibrates; the clock interval is adjusted up or down so that the clock tracks actual elapsed time. Operation at the fastest rates (100 usec, 1 msec) is not recommended. 2.4.7 12920A Terminal Multiplexor (MUXL, MUXU, MUXC) The 12920A is a 16-line terminal multiplexor, with five additional receive-only diagnostic lines. It consists of three devices: MUX scanning logic (corresponding more or less to the upper data card) MUXL individual lines (corresponding more or less to the lower data card) MUXC modem control and status logic (corresponding to the control card) The MUX performs input and output through Telnet sessions connected to a user-specified port. The ATTACH command to the scanning logic specifies the port to be used: ATTACH MUX set up listening port where port is a decimal number between 1 and 65535 that is not being used for other TCP/IP activities. Each line (each unit of MUXL) can be set to one of three modes: UC, 7B, or 8B. In UC mode, lower case input and output characters are converted automatically to upper case. In 7B mode, input and output characters are masked to 7 bits. In 8B mode, characters are not modified. The default mode is UC. In addition, each line supports the DATASET option. DATASET, when set, enables modem control. The default settings are UC mode and DATASET disabled. Finally, each line supports output logging. The SET MUXLn LOG command enables logging on a line: SET MUXLn LOG=filename log output of line n to filename The SET MUXLn NOLOG command disables logging and closes the open log file, if any. The modem controls model a simplified Bell 103A dataset with just four lines: data terminal ready and request to send from the computer to the data set, and carrier detect and data set ready from the data set to the computer. There is no ring detection. If data terminal ready is set when a Telnet connection starts up, then carrier detect and data set ready are also set. The connection is established whether data terminal ready is set or not. Once MUX is attached and the simulator is running, the multiplexor listens for connections on the specified port. It assumes that the incoming connections are Telnet connections. The connections remain open until disconnected either by the Telnet client, a SET MUXL DISCONNECT command, or a DETACH MUX command. The SHOW MUX CONNECTIONS command displays the current connections to the extra terminals. The SHOW MUX STATISTICS command displays statistics for active connections. The SET MUX DISCONNECT=linenumber disconnects the specified line. The scanner (MUX) implements these registers: name size comments IBUF 16 input buffer, holds line status OBUF 16 output buffer, holds channel select The lines (MUXL) implements these registers: name size comments CTL 1 device/interrupt enable FLG 1 device ready FBF 1 device ready buffer SRQ 1 device DMA service request STA[0:20] 16 line status, lines 0-20 RPAR[0:20] 16 receive parameters, lines 0-20 XPAR[0:15] 16 transmit parameters, lines 0-15 RBUF[0:20] 8 receive buffer, lines 0-20 XBUF[0:15] 8 transmit buffer, lines 0-15 RCHP[0:20] 1 receive character present, lines 0-20 XDON[0:15] 1 transmit done, lines 0-15 TIME[0:15] 24 transmit time, lines 0-15 The modem control (MUXM) implements these registers: name size comments CTL 1 device/interrupt enable FLG 1 device ready FBF 1 device ready buffer SRQ 1 device DMA service request SCAN 1 scan enabled CHAN 4 current line DSO[0:15] 6 C2,C1,ES2,ES1,SS2,SS1, lines 0-15 DSI[0:15] 2 S2,S1, lines 0-15 The terminal multiplexor does not support save and restore. All open connections are lost when the simulator shuts down or MUXU is detached. 2.4.8 Interprocessor Link (IPLI, IPLO) The interprocessor link is a pair of 12556B parallel interfaces that are cross coupled to provide interprocessor communications to a second copy of the HP2100 simulator. The IPL is intended to support simulation of a two system HP TimeShared Basic configuration. The links are actually bidirectional half-duplex; TimeShared Basic uses them unidirectionally. The IPL is disabled by default. To operate, the IPL devices must be enabled and then connected to the IPL devices in another copy of the simulator. The IPLI device in the first simulator is connected to the IPLO device in the second, and vice versa. Connections are established with the ATTACH command. One copy of the simulator listens for connections on a specified port (ATTACH -L); the other establishes connections to an IP address and port (ATTACH -C). Either copy may perform either operation, but the operations must be done in matched pairs: simulator #1 simulator #2 sim> set ipli ena sim> set ipli ena (also enables iplo) (also enables iplo) sim> att -lw ipli 4000 Listening on port 4000 Waiting for connection sim> att -c iplo 4000 Connection established Connected to 127.0.0.1 port 4000 sim> att -lw iplo 4000 Listening on port 4001 Waiting for connection sim> att -c ipli 4001 Connection established Connected to 127.0.0.1 port 4000 Both forms of ATTACH take a modifier -W (wait); if specified, the command will wait up to 30 seconds for the connection process to complete. ATTACH -C can specify both an IP address and a port, in the form aa.bb.cc.dd:port; if the IP address is omitted, it defaults to 127.0.0.1 (local system). Both IPLI and IPLO implement the BOOT command. BOOT loads the HP Access Basic Block Loader for the IOP into the top 64 words of memory and starts it running. Both IPLI and IPLO implement these registers: name size comments BUF 16 buffer HOLD 8 holding buffer CMD 1 device enable CTL 1 device/interrupt enable FLG 1 device ready FBF 1 device ready buffer SRQ 1 device DMA service request TIME 24 polling interval for input STOP_IOE 1 stop on I/O error 2.5 12557A Disk Controller (DPC, DPD) with 2781 Drives 13210A Disk Controller (DPC, DPD) with 7900 Drives The 12557A/13210A disk controller can be configured as either a 12557A, supporting 2.5MB drives, or a 13210A, supporting 5MB drives, with the commands: SET DPC 12557A 2.5MB drives SET DPC 13210A 5.0MB drives Drive types cannot be intermixed; the controller is configured for one type or the other. The 13210A (for 7900/7901 disks) is selected by default. The simulated controller has two separate devices, a data channel and a device controller. The data channel includes a 128-word (one sector) buffer for reads and writes. The device controller includes the four disk drives. Disk drives can be set ONLINE or OFFLINE. The 12557A/13210A supports the BOOT command. BOOT DPC copies the IBL for 7900 class disks into memory and starts it running. BOOT -R DPC boots from the removable platter (head 2). The switch register (S) is set automatically to the value expected by the IBL loader: <15:14> = 01 <13:12> = 00 <11:6> = data channel device code <5:3> = unchanged <2:1> = 00 <0> = 1 if booting from the removable platter The data channel implements these registers: name size comments IBUF 16 input buffer OBUF 16 output buffer DBUF[0:127] 16 sector buffer BPTR 7 sector buffer pointer CMD 1 channel enable CTL 1 interrupt enable FLG 1 channel ready FBF 1 channel ready buffer SRQ 1 channel DMA service request XFER 1 transfer in progress flag WVAL 1 write data valid flag The device controller implements these registers: name size comments OBUF 16 output buffer BUSY 4 busy (unit #, + 1, of active unit) CNT 5 check record count CMD 1 controller enable CTL 1 interrupt enable FLG 1 controller ready FBF 1 controller ready buffer SRQ 1 controller DMA service request EOC 1 end of cylinder pending POLL 1 attention polling enabled RARC[0:3] 8 record address register cylinder, drives 0-3 RARH[0:3] 2 record address register head, drives 0-3 RARS[0:3] 4 record address register sector, drives 0-3 STA[0:3] 16 drive status, drives 0-3 CTIME 24 data transfer command delay time DTIME 24 data channel command delay time STIME 24 seek delay time, per cylinder XTIME 24 interword transfer time Error handling is as follows: error processed as not attached disk not ready end of file assume rest of disk is zero OS I/O error report error and stop 2.6 12565A Disk Controller (DQC, DQD) with 2883 Drives The 12565A disk controller has two separate devices, a data channel and a device controller. The data channel includes a 128-word (one sector) buffer for reads and writes. The device controller includes the two disk drives. Disk drives can be set ONLINE or OFFLINE. The 12565A supports the BOOT command. BOOT DQC copies the IBL for 2883 class disks into memory and starts it running. The switch register (S) is set automatically to the value expected by the IBL loader: <15:12> = 0110 <11:6> = data channel device code <5:3> = unchanged <2:0> = 000 The data channel implements these registers: name size comments IBUF 16 input buffer OBUF 16 output buffer DBUF[0:127] 16 sector buffer BPTR 7 sector buffer pointer CMD 1 channel enable CTL 1 interrupt enable FLG 1 channel ready FBF 1 channel ready buffer SRQ 1 channel DMA service request XFER 1 transfer in progress flag WVAL 1 write data valid flag The device controller implements these registers: name size comments OBUF 16 output buffer BUSY 2 busy (unit #, + 1, of active unit) CNT 9 check record count CMD 1 controller enable CTL 1 interrupt enable FLG 1 controller ready FBF 1 controller ready buffer SRQ 1 controller DMA service request RARC[0:1] 8 record address register cylinder, drives 0-1 RARH[0:1] 5 record address register head, drives 0-1 RARS[0:1] 5 record address register sector, drives 0-1 STA[0:1] 16 drive status, drives 0-3 CTIME 24 data transfer command delay time DTIME 24 data channel command delay time STIME 24 seek delay time, per cylinder XTIME 24 interword transfer time Error handling is as follows: error processed as not attached disk not ready end of file assume rest of disk is zero OS I/O error report error and stop 2.7 12606B Fixed Head Disk Controller (DRC, DRD) with 2770/2771 Disk 12610B Drum Controller (DRC, DRD) with 2773/2774/2775 Drum The 12606B/12610B fixed head disk/drum controller has two separate devices, a data channel and a device controller. The device controller includes the actual drive. Ten different models are supported: SET DRC 180K 12606B, 180K words SET DRC 360K 12606B, 360K words SET DRC 720K 12606B, 720K words SET DRC 384K 12610B, 84K words SET DRC 512K 12610B, 512K words SET DRC 640K 12610B, 640K words SET DRC 768K 12610B, 768K words SET DRC 896K 12610B, 896K words SET DRC 1024K 12610B, 1024K words SET DRC 1536K 12610B, 1536K words The 12606B/12610B support the BOOT command. The BOOT command loads the first sector from the disk or drum into locations 0-77 and then jumps to 77. This is very different from the IBL loader protocol used by the 12565A and the 12557A/13210A. The data channel implements these registers: name size comments IBUF 16 input buffer OBUF 16 output buffer CMD 1 channel enable CTL 1 interrupt enable FLG 1 channel ready FBF 1 channel ready buffer SRQ 1 channel DMA service request BPTR 6 sector buffer pointer The device controller implements these registers: name size comments CW 16 command word STA 16 status CMD 1 controller enable CTL 1 interrupt enable FLG 1 controller ready FBF 1 controller ready buffer SRQ 1 controller DMA service request TIME 24 interword transfer time STOP_IOE 1 stop on I/O error Error handling is as follows: error processed as not attached disk not ready 12606B/12610B data files are buffered in memory; therefore, end of file and OS I/O errors cannot occur. 2.8 12559C Magnetic Tape Controller (MTC, MTD) with 3030 Drive Magnetic tape options include the ability to make the unit write enabled or write locked. SET MTC LOCKED set unit write locked SET MTC WRITEENABLED set unit write enabled The 12559C mag tape drive has two separate devices, a data channel and a device controller. The data channel includes a maximum record sized buffer for reads and writes. The device controller includes the tape unit. The BOOT command is not supported. The 12559C was HP's earliest tape drive and is not supported by most of its operating systems. It is disabled by default. The data channel implements these registers: name size comments FLG 1 channel ready SRQ 1 channel DMA service request DBUF[0:65535] 8 transfer buffer BPTR 16 buffer pointer (reads and writes) BMAX 16 buffer size (writes) The device controller implements these registers: name size comments FNC 8 current function STA 9 tape status BUF 8 buffer CTL 1 interrupt enabled FLG 1 controller ready FBF 1 controller ready buffer SRQ 1 controller DMA service request DTF 1 data transfer flop FSVC 1 first service flop POS 32 magtape position CTIME 24 command delay time XTIME 24 interword transfer delay time STOP_IOE 1 stop on I/O error Error handling is as follows: error processed as not attached tape not ready; if STOP_IOE, stop end of file parity error OS I/O error parity error; if STOP_IOE, stop 2.9 13181A Magnetic Tape Controller (MSC, MSD) with 7970B Drives 18183A Magnetic Tape Controller (MSC, MSD) with 7970E Drives Magnetic tape options include the ability to make the unit write enabled or write locked, and the ability to select the 13181A (800 bpi) controller or the 13183A (1600 bpi) controller. SET MSCn LOCKED set unit n write locked SET MSCn WRITEENABLED set unit n write enabled SET MSC 13181A set controller to 13181A SET MSC 13183A set controller to 13183A SET MSC REALTIME set controller to actual timing SET MSC FASTIME set controller to optimized timing (default) SET MSCn REEL=length set unit tape reel size 0 = unlimited (default) 600 = 600 feet 1200 = 1200 feet 2400 = 2400 feet The 13181A/13183A mag tape drive has two separate devices, a data channel and a device controller. The data channel includes a maximum record sized buffer for reads and writes. The device controller includes the tape units. The 13181A/13183A supports the BOOT command. BOOT MSC loads the IBL for 7970B/E magnetic tape drives into memory and starts it running. BOOT -S MSC causes the loader to space forward the number of files specified in the A register before starting to load data. The switch register (S) is set automatically to the value expected by the IBL loader: <15:12> = 1000 <11:6> = data channel device code <5:3> = unchanged <2:0> = 00 <0> = 1 if space forward before loading The data channel implements these registers: name size comments BUF 16 data buffer CTL 1 interrupt enabled FLG 1 channel ready FBF 1 channel ready buffer SRQ 1 channel DMA service request DBUF[0:65535] 8 transfer buffer BPTR 17 buffer pointer (reads and writes) BMAX 17 buffer size (writes) The device controller implements these registers: name size comments STA 12 tape status BUF 16 buffer USEL 2 currently selected unit FSVC 1 first service flop CTL 1 interrupt enabled FLG 1 controller ready FBF 1 controller ready buffer SRQ 1 controller DMA service request POS[0:3] 32 magtape position BTIME 24 BOT start delay time CTIME 24 command delay time GTIME 24 gap traversal time ITIME 24 IRG traversal time RTIME 24 rewind initiation time XTIME 24 interword transfer delay time STOP_IOE 1 stop on I/O error Error handling is as follows: error processed as not attached tape not ready; if STOP_IOE, stop end of file parity error OS I/O error parity error; if STOP_IOE, stop 2.10 Symbolic Display and Input The HP2100 simulator implements symbolic display and input. Display is controlled by command line switches: -a display as ASCII character -c display as two character string -m display instruction mnemonics Input parsing is controlled by the first character typed in or by command line switches: ' or -a ASCII character " or -c two character sixbit string alphabetic instruction mnemonic numeric octal number Instruction input uses standard HP2100 assembler syntax. There are seven instruction classes: memory reference, I/O, shift, alter skip, extended shift, extended memory reference, extended two address reference. Memory reference instructions have the format memref {C/Z} address{,I} where I signifies indirect, C a current page reference, and Z a zero page reference. The address is an octal number in the range 0 - 077777; if C or Z is specified, the address is a page offset in the range 0 - 01777. Normally, C is not needed; the simulator figures out from the address what mode to use. However, when referencing memory outside the CPU (eg, disks), there is no valid PC, and C must be used to specify current page addressing. IOT instructions have the format io device{,C} where C signifies that the device flag is to be cleared. The device is an octal number in the range 0 - 77. Shift and alter/skip instructions have the format sub-op sub-op sub-op... The simulator checks that the combination of sub-opcodes is legal. Extended shift instructions have the format extshift count where count is an octal number in the range 1 - 020. Extended memory reference instructions have the format extmemref address{,I} where I signifies indirect addressing. The address is an octal number in the range 0 - 077777. Extended two address instructions have the format ext2addr addr1{,I},addr2{,I} where I signifies indirect addressing. Both address 1 and address 2 are octal numbers in the range 0 - 077777.