To: Users From: Bob Supnik Subj: Interdata 16b/32b Simulator Usage Date: 15-Feb-2004 COPYRIGHT NOTICE The following copyright notice applies to both the SIMH source and binary: Original code published in 1993-2004, written by Robert M Supnik Copyright (c) 1993-2004, Robert M Supnik Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files (the "Software"), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge, publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is furnished to do so, subject to the following conditions: The above copyright notice and this permission notice shall be included in all copies or substantial portions of the Software. THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL ROBERT M SUPNIK BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE. Except as contained in this notice, the name of Robert M Supnik shall not be used in advertising or otherwise to promote the sale, use or other dealings in this Software without prior written authorization from Robert M Supnik. This memorandum documents the Interdata 16b and 32b simulators. 1. Simulator Files sim/ scp.h sim_console.h sim_defs.h sim_fio.h sim_rev.h sim_sock.h sim_tape.h sim_timer.h sim_tmxr.h scp.c sim_console.c sim_fio.c sim_sock.c sim_tape.c sim_timer.c sim_tmxr.c sim/interdata/ id_defs.h id16_cpu.c [id32_cpu.c] id16_dboot.c [id32_dboot.c] id_dp.c id_fd.c id_fp.c id_idc.c id_io.c id_lp.c id_mt.c id_pas.c id_pt.c id_tt.c id_ttp.c id_uvc.c id16_sys.c [id32_sys.c] 2. Interdata Features The Interdata simulator includes simulators for a variety of 16b (I3, I4, I5, 70, 80, 7/16, 8/16, 8/16E) and 32b (7/32, 8/32) models. This is by no means a complete sampling of all the variations in the Interdata/Perkin- Elmer family. The 32b family included options for special communications instructions (7/32C, 8/32C), as well as a later extension for virtual memory (3200 series). The Interdata simulator is configured as follows: device simulates name(s) CPU - 16b Interdata 3, 4, 5, 70, 80, 7/16, or 8/16 CPU with 64KB memory Interdata 8/16E CPU with 256KB memory CPU - 32b Interdata 7/32 or 8/32 CPU with 1MB memory SELCH selector channel (1-4) PT paper tape reader/punch TT console terminal, Teletype interface TTP console terminal, PASLA interface LFC line frequency clock PIC programmable interval clock LPT line printer FD floppy disk DP 2.5MB/10MB cartridge disk DM mass storage module (MSM)/intelligent (IDC) disk controller MT magnetic tape PAS programmable asynchronous line controller PASL programmable asynchronous lines, up to 32 The Interdata simulator implements two unique stop conditions: - decode of an undefined instruction, and STOP_INST is set - runaway carriage control tape in the line printer. The LOAD command is used to load a carriage control tape for the line printer. The DUMP command is used to dump a contiguous portion of memory as a self-loading bootstrap paper tape. The syntax for the DUMP command is: DUMP lowaddr-highaddr The low address must be greater than or equal to X'D0'. Devices are assigned their default device numbers, as documented in the Interdata literature. Device numbers can be changed by the command: SET DEVNO=num Device number conflicts are not checked until simulation starts. If there is a device number conflict, simulation stops immediately with an error message. Selector channel devices are assigned by default to selector channel 0. Selector channel assignments can be changed by the command: SET SELCH=num Selector channel assignments cannot introduce conflicts. Most devices can be disabled and enabled, with the commands: SET DISABLED SET ENABLED All devices are enabled by default. 2.1 CPU (16b) The CPU options include memory size and CPU type: SET CPU I3 Interdata 3 (base instruction set) SET CPU I4 Interdata 4 (base plus single precision floating point) SET CPU 716 Interdata 7/16 (extended instruction set) (equivalent to Models 5, 70, and 80) SET CPU 816 Interdata 8/16 (extended plus double precision floating point) SET CPU 816E Interdata 8/16E (extended plus double precision plus expanded memory) SET CPU 8K set memory size = 8KB SET CPU 16K set memory size = 16KB SET CPU 24K set memory size = 24KB SET CPU 32K set memory size = 32KB SET CPU 48K set memory size = 48KB SET CPU 64K set memory size = 64KB SET CPU 128K set memory size = 128KB (8/16E only) SET CPU 256K set memory size = 256KB (8/16E only) SET CPU CONSINT assert console interrupt (7/16, 8/16, and 8/16E only) If memory size is being reduced, and the memory being truncated contains non-zero data, the simulator asks for confirmation. Data in the truncated portion of memory is lost. Initial memory size is 64KB. These switches are recognized when examining or depositing in CPU memory (or any other byte oriented device): -b examine/deposit bytes -w examine/deposit halfwords (CPU default) -f examine/deposit fullwords -d data radix is decimal -o data radix is octal -h data radix is hexadecimal -v interpret address as virtual CPU registers include the visible state of the processor as well as the control registers for the interrupt system. name size comments PC 16 program counter R0..R15 16 general registers FR0..F14 32 single precision floating point registers D0H..D14H 32 double precision floating point registers, high order D0L..D14L 32 double precision floating point registers, low order PSW 16 processor status word CC 4 condition codes, PSW<12:15> SR 16 switch register DR 32 display register low 16 bits DRX 8 display register extension (x/16 only) DRMOD 1 display mode DRPOS 2 display pointer position SRPOS 1 switch pointer position IRQ[0:3] 32 interrupt requests IEN[0:3] 32 interrupt enables STOP_INST 1 stop on undefined instruction STOP_WAIT 1 stop if wait state and no I/O events pending PCQ[0:63] 16 PC prior to last branch or interrupt; most recent PC change first WRU 8 interrupt character 2.2 CPU (32b) The CPU options include memory size and CPU type: SET CPU 732 Interdata 7/32, single precision floating point SET CPU DPFP Interdata 7/32, double precision floating point SET CPU 832 Interdata 8/32 (double precision floating point) SET CPU 64K set memory size = 64KB SET CPU 128K set memory size = 128KB SET CPU 256K set memory size = 256KB SET CPU 512K set memory size = 512KB SET CPU 1M set memory size = 1024KB SET CPU CONSINT assert console interrupt If memory size is being reduced, and the memory being truncated contains non-zero data, the simulator asks for confirmation. Data in the truncated portion of memory is lost. Initial memory size is 1024KB. These switches are recognized when examining or depositing in CPU memory (or any other byte oriented device): -b examine/deposit bytes -w examine/deposit halfwords -f examine/deposit fullwords (CPU default) -d data radix is decimal -o data radix is octal -h data radix is hexadecimal -v interpret address as virtual CPU registers include the visible state of the processor as well as the control registers for the interrupt system. name size comments PC 20 program counter R0..R15 32 active general register set GREG[32] 32 general register sets, 16 x 2 FR0..FR14 32 single precision floating point registers D0H..D14H 32 double precision floating point registers, high order D0L..D14L 32 double precision floating point registers, low order PSW 16 processor status word CC 4 condition codes, PSW<12:15> SR 16 switch register DR 32 display register low 16 bits DRX 8 display register extension (x/16 only) DRMOD 1 display mode DRPOS 2 display pointer position SRPOS 1 switch pointer position MACREG[0:15] 32 memory access controller segment registers MACSTA 5 memory access controller interrupt status IRQ[0:3] 32 interrupt requests IEN[0:3] 32 interrupt enables STOP_INST 1 stop on undefined instruction STOP_WAIT 1 stop if wait state and no I/O events pending PCQ[0:63] 20 PC prior to last branch or interrupt; most recent PC change first WRU 8 interrupt character The CPU can maintain a history of the most recently executed instructions. This is controlled by the SET CPU HISTORY and SHOW CPU HISTORY commands: SET CPU HISTORY clear history buffer SET CPU HISTORY=0 disable history SET CPU HISTORY=n enable history, display length = n SHOW CPU HISTORY print CPU history The maximum length for the history is 65536 entries. 2.3 Selector Channel (SELCH) An Interdata system can have 1 to 4 selector channels (SELCH0, SELCH1, SELCH2, SELCH3). The default number of channels is 2. The number of channels can be changed with the command: SET SELCH CHANNELS=num All the state for a selector channel can be displayed with the command: SHOW SELCH num The selector channels implement these registers: name size comments SA[0:3] 20 start address, channels 0 to 3 EA[0:3] 20 end address, channels 0 to 3 CMD[0:3] 8 command, channels 0 to 3 DEV[0:3] 8 active device, channels 0 to 3 RDP[0:3] 2 read byte pointer, channels 0 to 3 WDC[0:3] 3 write data counter, channels 0 to 3 IREQ 4 interrupt requests; right to left, channels 0 to 3 IENB 4 interrupt enables 2.4 Programmed I/O Devices 2.4.1 Paper Tape Reader/Punch (PT) The paper tape reader and punch (PT units 0 and 1) read data from or write data to disk files. The RPOS and PPOS registers specify the number of the next data item to be read and written, respectively. Thus, by changing RPOS or PPOS, the user can backspace or advance these devices. The paper tape reader supports the BOOT command. BOOT PTR copies the so-called '50 loader' into memory and starts it running. The paper tape controller implements these registers: name size comments RBUF 8 reader buffer RPOS 32 reader position in the input file RTIME 24 time from reader start to interrupt RSTOP_IOE 1 reader stop on I/O error PBUF 8 punch buffer PPOS 32 punch position in the output file PTIME 24 time from punch start to interrupt PSTOP_IOE 1 punch stop on I/O error IREQ 1 paper tape interrupt request IENB 1 paper tape interrupt enable IARM 1 paper tape interrupt armed RD 1 paper tape read/write mode RUN 1 paper tape running SLEW 1 paper tape reader slew mode EOF 1 paper tape reader end of file Error handling is as follows: type error STOP_IOE processed as in,out not attached 1 report error and stop 0 out of tape in end of file 1 report error and stop 0 out of tape in,out OS I/O error x report error and stop 2.4.2 Console, Teletype Interface (TT) The Teletype keyboard (TT0) reads from the console keyboard; the Teletype printer (TT1) writes to the simulator console window. The Teletype units (TT0, TT1) can be set to one of three modes: KSR, 7B, or 8B. In KSR mode, lower case input and output characters are automatically converted to upper case, and the high order bit is forced to one on input. In 7B mode, input and output characters are masked to 7 bits. In 8B mode, characters are not modified. Changing the mode of either unit changes both. The default mode is KSR. The Teletype has a BREAK key, which is not present on today's keyboards. To simulate pressing the break key, stop the simulator and use the command: SET TT BREAK Break status will be asserted, and will remain asserted for the interval specified by KTIME. The Teletype interface implements these registers: name size comments KBUF 8 input buffer KPOS 32 number of characters input KTIME 24 input polling interval TBUF 8 output buffer TPOS 32 number of characters output TTIME 24 time from output start to interrupt IREQ 1 interrupt request IENB 1 interrupt enable IARM 1 interrupt armed RD 1 read/write mode FDPX 1 half-duplex CHP 1 input character pending 2.4.3 Console, PASLA Interface (TTP) Later Interdata system connect the system console via the first PASLA interface rather than the Teletype interface. The PASLA console can be simulated with a Telnet session on the first PAS line. Alternately, the PASLA console can be attached to the simulator console window, using the TTP device in place of TT. To switch the simulator console window to TTP, use the command: SET TTP ENABLED or SET TT DISABLED Device TT is automatically disabled and device TTP is enabled. To switch the simulator console window back to TT, use the command: SET TT ENABLED or SET TTP DISABLED Device TTP is automatically disabled and device TT is enabled. If TTP is enabled at its default device settings, the base address for the PAS multiplexor must be changed: SET PAS DEVNO=12 Otherwise, a device number conflict occurs. The PASLA keyboard (TTP0) reads from the console keyboard; the PALSA printer (TTP1) writes to the simulator console window. The PASLA units (TTP0, TTP1) can be set to one of three modes: UC, 7B, or 8B. In UC mode, lower case input and output characters are automatically converted to upper case. In 7B mode, input and output characters are masked to 7 bits. In 8B mode, characters are not modified. Changing the mode of either unit changes both. The default mode is 7B. To simulate pressing the break key, stop the simulator and use the command: SET TTP BREAK Break status will be asserted, and will remain asserted for the interval specified by KTIME. The PASLA console interface implements these registers: name size comments CMD 16 command register STA 8 status register KBUF 8 input buffer KPOS 32 number of characters input KTIME 24 input polling interval KIREQ 1 input interrupt request KIENB 1 input interrupt enabled KARM 1 input interrupt armed CHP 1 input character pending TBUF 8 output buffer TPOS 32 number of characters output TTIME 24 time from output start to interrupt TIREQ 1 output interrupt request TIENB 1 output interrupt enable TIARM 1 output interrupt armed 2.4.4 Line Printer (LPT) The line printer (LPT) writes data to a disk file. The POS register specifies the number of the next data item to be written. Thus, by changing POS, the user can backspace or advance the printer. In addition, the line printer can be programmed with a carriage control tape. The LOAD command loads a new carriage control tape: LOAD load carriage control tape file The format of a carriage control tape consists of multiple lines. Each line contains an optional repeat count, enclosed in parentheses, optionally followed by a series of column numbers separated by commas. Column numbers must be between 0 and 7; column seven is by convention top of form. The following are all legal carriage control specifications: no punch (5) 5 lines with no punches 1,5,7 columns 1, 5, 7 punched (10)2 10 lines with column 2 punched 0 column 0 punched The default form is 1 line long, with all columns punched. The line printer implements these registers: name size comments BUF 7 last data item processed BPTR 8 line buffer pointer LBUF[0:131] 7 line buffer VFUP 8 vertical forms unit pointer VFUL 8 vertical forms unit length VFUT[0:131] 8 vertical forms unit table IREQ 1 line printer interrupt request IENB 1 line printer interrupt enable IARM 1 line printer interrupt armed POS 32 position in the output file CTIME 24 character processing time STIME 24 spacing operation time STOP_IOE 1 stop on I/O error Error handling is as follows: error STOP_IOE processed as not attached 1 report error and stop 0 out of paper OS I/O error x report error and stop 2.4.5 Line Frequency Clock (LFC) The line frequency clock (LFC) frequency can be adjusted as follows: SET LFC 60HZ set frequency to 60Hz SET LFC 50HZ set frequency to 50Hz The default is 60Hz. The line frequency clock implements these registers: name size comments IREQ 1 clock interrupt request IENB 1 clock interrupt enable IARM 1 clock interrupt armed TIME 24 clock frequency The line frequency clock autocalibrates; the clock interval is adjusted up or down so that the clock tracks actual elapsed time. 2.4.6 Programmable Interval Clock (PIC) The programmable interval clock (PIC) implements these registers: name size comments BUF 16 output buffer RIC 16 reset interval and rate CIC 12 current interval DECR 10 current decrement value RDP 1 read byte select OVF 1 interval overflow flag IREQ 1 clock interrupt request IENB 1 clock interrupt enable IARM 1 clock interrupt armed If the interval requested is an exact multiple of 1 msec, the programmable clock auto-calibrates; if not, it counts instructions. 2.4.7 Floppy Disk Controller (FD) Floppy disk options include the ability to make units write enabled or write locked. SET FDn LOCKED set unit n write locked SET FDn WRITEENABLED set unit n write enabled Units can also be set ONLINE or OFFLINE. The floppy disk supports the BOOT command. BOOT FDn copies an autoload sequence into memory and starts it running. The floppy disk controller implements these registers: name size comments CMD 8 command STA 8 status BUF 8 buffer LRN 16 logical record number ESTA[0:5] 8 extended status bytes DBUF[0:127] 8 transfer buffer DBPTR 8 transfer buffer pointer IREQ 1 interrupt request IENB 1 interrupt enabled IARM 1 interrupt armed CTIME 24 command response time STIME 24 seek time, per cylinder XTIME 24 transfer time, per byte STOP_IOE 1 stop on I/O error Error handling is as follows: error STOP_IOE processed as not attached 1 report error and stop 0 disk not ready Floppy disk data is buffered in memory; therefore, end of file and OS I/O errors cannot occur. 2.4.8 Programmable Asynchronous Line Adapters (PAS, PASL) The Programmable Asynchronous Line Adapters (PAS and PASL) represent, indistinguishably, individual PASLA interfaces, two lines asynchronous multiplexors, and 8 line asynchronous multiplexors, with a maximum of 32 lines. All the lines are modelled as a terminal multiplexor, with PAS as the multiplexor controller, and PASL as the indivdual lines. The PASLAs perform input and output through Telnet sessions connected to a user-specified port. The ATTACH command specifies the port to be used: ATTACH PAS set up listening port where port is a decimal number between 1 and 65535 that is not being used for other TCP/IP activities. Each line (each unit of PASL) can be set to one of three modes: UC, 7B, or 8B. In UC mode, lower case input and output characters are converted automatically to upper case. In 7B mode, input and output characters are masked to 7 bits. In 8B mode, characters are not modified. The default mode is UC. Each line (each unit of PASL) can also be set for modem control with the command SET PASLn DATASET. The defaults are 7b mode and DATASET disabled. Finally, each line supports output logging. The SET PASLn LOG command enables logging on a line: SET PASLn LOG=filename log output of line n to filename The SET PASLn NOLOG command disables logging and closes the open log file, if any. Once PAS is attached and the simulator is running, the terminals listen for connections on the specified port. They assume that the incoming connections are Telnet connections. The connections remain open until disconnected either by the Telnet client, a SET PAS DISCONNECT command, or a DETACH PAS command. The SHOW PAS CONNECTIONS command displays the current connections to the extra terminals. The SHOW PAS STATISTICS command displays statistics for active connections. The SET PAS DISCONNECT=linenumber disconnects the specified line. The controller (PAS) implements these registers: name size comments STA[0:31] 8 status, lines 0 to 31 CMD[0:31] 16 command, lines 0 to 31 RBUF[0:31] 8 receive buffer, lines 0 to 31 XBUF[0:31] 8 transmit buffer, lines 0 to 31 RIREQ 32 receive interrupt requests; right to left, lines 0 to 31 RIENB 32 receive interrupt enables RARM[0:31] 1 receive interrupt armed XIREQ 32 transmit interrupt requests; right to left, lines 0 to 31 XIENB 32 transmit interrupt enables XARM[0:31] 1 transmit interrupt armed RCHP[0:31] 1 receiver character present, lines 0 to 31 The lines (PASL) implements these registers: name size comments TIME[0:31] 24 transmit time, lines 0 to 31 The additional terminals do not support save and restore. All open connections are lost when the simulator shuts down or PAS is detached. 2.5 Cartridge Disk Controller (DP) Cartridge disk options include the ability to make units write enabled or write locked, and to select the type of drive: SET DPn LOCKED set unit n write locked SET DPn WRITEENABLED set unit n write enabled SET DPn 2315 set unit n to 2315 (2.5MB) SET DPn 5440 set unit n to 5440 (10MB) Units can also be set ONLINE or OFFLINE. The cartridge disk supports the BOOT command. To boot OS16/32, the hex form of the operating system file's extension must be placed in locations 7E:7F. The disk bootstrap looks for a valid OS16/32 volume descriptor in block 0, and uses that to locate the volume directory. It then searches the directory for a filename of the form OS16xxxx.hhh or OS32xxxx.hhh, where the xxxx is ignored and hhh is the ASCII form of the extension from locations 7E:7F. The 32b bootstrap can also boot Wollongong UNIX; locations 7E:7F must be 0. The bootstrap normally boots from the first (removable) platter in a 5440; to boot from the second (fixed) platter, use BOOT -F. All drives have 256 8b bytes per sector. The other disk parameters are: drive cylinders surfaces sectors 2315 203 2 24 5440 408 4 12 The cartridge disk controller implements these registers: name size comments CMD 3 current command STA 8 controller status BUF 8 controller buffer HDSC 8 current head/sector select CYL 8 current cylinder select DBUF[0:255] 8 transfer buffer DBPTR 16 transfer buffer point DBLNT 16 transfer buffer length FIRST 1 first DMA service flag IREQ 5 interrupt requests; right-to-left, controller, drives 0 to 3 IENB 5 interrupt enables IARM[0:3] 1 interrupts armed, drives 0 to 3 STIME 24 seek latency, per cylinder RTIME 24 rotational latency, per sector WTIME 24 inter-word latency Error handling is as follows: error processed as not attached disk not ready end of file assume rest of disk is zero OS I/O error report error and stop 2.6 Mass Storage Module/Intelligent Disk Controller (DM) MSM/IDC disk controller options include the ability to make units write enabled or write locked, and to select the type of drive: SET DMn LOCKED set unit n write locked SET DMn WRITEENABLED set unit n write enabled SET DMn MSM80 set unit n to storage module, 80MB (67MB formatted) SET DMn MSM300 set unit n to storage module, 300MB (262MB formatted) SET DMn MCCD16 set unit n to medium capacity, 16MB (13.5MB formatted) SET DMn MCCD48 set unit n to medium capacity, 48MB (40.5MB formatted) SET DMn MCCD80 set unit n to medium capacity, 80MB (67MB formatted) SET DMn MSM330F set unit n to storage module, 330MB (300MB formatted) Note that the disk bootstraps can ONLY boot the MSM80 and MSM300. Units can be set ONLINE or OFFLINE. The MSM/IDC controller supports the BOOT command. To boot OS16/32, the hex form of the operating system file's extension must be placed in locations 7E:7F. The disk bootstrap looks for a valid OS16/32 volume descriptor in block 0, and uses that to locate the volume directory. It then searches the directory for a filename of the form OS16xxxx.hhh or OS32xxxx.hhh, where the xxxx is ignored and hhh is the ASCII form of the extension from locations 7E:7F. The 32b bootstrap can also boot Wollongong UNIX; locations 7E:7F must be 0. Note that only the MSM80 and MSM300 drives can be boot- strapped; the boot code does not recognize the other drives. All drives have 256 8b bytes per sector. The other disk parameters are: drive cylinders surfaces sectors MSM80 823 5 64 MSM300 823 19 64 MCCD16 823 1 64 MCCD48 823 3 64 MCCD80 823 5 64 MSM300F 1024 16 64 The MSM/IDC disk controller implements these registers: name size comments STA 8 controller status BUF 8 controller buffer SEC 8 current sector select DBUF[0:767] 8 transfer buffer DBPTR 16 transfer buffer point DBLNT 16 transfer buffer length FIRST 1 first DMA service flag IREQ 5 interrupt requests; right-to-left, controller, drives 0 to 3 IENB 5 interrupt enables SIREQ 5 saved interrupt requests ICARM 1 controller interrupt armed IDARM[0:3] 1 drive interrupts armed, drives 0 to 3 STIME 24 seek latency, per cylinder RTIME 24 rotational latency, per sector WTIME 24 inter-word latency Error handling is as follows: error processed as not attached disk not ready end of file assume rest of disk is zero OS I/O error report error and stop 2.7 Magnetic Tape Controller (MT) Magnetic tape options include the ability to make units write enabled or or write locked. SET MTn LOCKED set unit n write locked SET MTn WRITEENABLED set unit n write enabled Units can also be set ONLINE or OFFLINE. The magnetic tape supports the BOOT command. BOOT MTn copies an autoload sequence into memory and starts it running. The magnetic tape controller implements these registers: name size comments CMD 8 command STA 8 status BUF 8 buffer DBUF[0:65535] 8 transfer buffer DBPTR 16 transfer buffer pointer DBLNT 16 transfer buffer length XFR 1 transfer in progress flag FIRST 1 first DMA service flag IREQ 4 interrupt requests; right to left, drives 0 to 3 IENB 4 interrupt enables IARM[0:3] 1 interrupts armed, drives 0 to 3 STOP_IOE 1 stop on I/O error WTIME 1 word transfer time RTIME 1 interrecord latency UST[0:3] 8 unit status, drives 0 to 3 POS[0:3] 32 tape position, drives 0 to 3 Error handling is as follows: error processed as not attached tape not ready; if STOP_IOE, stop end of file set error flag OS I/O error set error flag; if STOP_IOE, stop 2.8 Symbolic Display and Input The Interdata simulator implements symbolic display and input. Display is controlled by command line switches: -a display as ASCII character -c display as two character string -m display instruction mnemonics Input parsing is controlled by the first character typed in or by command line switches: ' or -a ASCII character " or -c two character sixbit string alphabetic instruction mnemonic numeric octal number 2.8.1 16b Instruction Input Instruction input uses standard Interdata assembler syntax. There are seven instruction classes: short branch, extended short branch, short immediate, register, register-register, memory, and register-memory. Short branch instructions have the format sbop mask,address where the mask is a hex (decimal) number between 0 and F (15), and the address is within +32 (forward branch) or -32 (backward branch) of the current location. Extended short branch instructions have the format sbxop address where the address is within +32 or -32 of the current location. For extended short branches, the simulator chooses the forward or backward direction automatically. Short immediate instructions have the format siop regnum,immed where the register number is a hex (decimal) number, optionally preceded by R, between 0 and F (15), and the immediate is a hex digit between 0 and F. Register instructions have the format rop regnum where the register number is a hex (decimal) number, optionally preceded by R, between 0 and F (15). Register-register instructions have the format rrop regnum,regnum where the register numbers are hex (decimal) numbers, optionally preceded by R, between 0 and F (15). Memory instructions have the format mop address{(index)} where address is a hex number between 0 and 0xFFFF, and the index register is a hex (decimal) number, optionally preceded by R, between 1 and F (15). Register-memory instructions have the format rmop regnum,address{(index)} where the register number is a hex (decimal) number, optionally preceded by R, between 0 and F (15), the address is a hex number between 0 and 0xFFFF, and the index register is a hex (decimal) number, optionally preceded by R, between 1 and F (15). 2.8.2 32b Instruction Input Instruction input uses standard Interdata assembler syntax. There are nine instruction classes: short branch, extended short branch, short immediate, 16b immediate, 32b immediate, register, register-register, memory, and register-memory. Addresses, where required, can be specified as either absolute numbers or relative to the current location (.+n or .-n). Short branch instructions have the format sbop mask,address where the mask is a hex (decimal) number between 0 and F (15), and the address is within +32 (forward branch) or -32 (backward branch) of the current location. Extended short branch instructions have the format sbxop address where the address is within +32 or -32 of the current location. For extended short branches, the simulator chooses the forward or backward direction automatically. Short immediate instructions have the format siop regnum,immed where the register number is a hex (decimal) number, optionally preceded by R, between 0 and F (15), and the immediate is a hex digit between 0 and F. 16b immediate instructins have the format i16op regnum,immed16{(index)} where the register number is a hex (decimal) number, optionally preceded by R, between 0 and F (15), the immediate is a hex number between 0 and 0xFFFF, and the index register is a hex (decimal) number, optionally preceded by R, between 1 and F (15). 32b immediate instructions have the format i32op regnum,immed32{(index)} where the register number is a hex (decimal) number, optionally preceded by R, between 0 and F (15), the immediate is a hex number between 0 and 0xFFFFFFFF, and the index register is a hex (decimal) number, optionally preceded by R, between 1 and F (15). Register instructions have the format rop regnum where the register number is a hex (decimal) number, optionally preceded by R, between 0 and F (15). Register-register instructions have the format rrop regnum,regnum where the register numbers are hex (decimal) numbers, optionally preceded by R, between 0 and F (15). Memory instructions have the format mop address{(index)} or mop address{(index1,index2)} where address is a hex number between 0 and 0xFFFF, and the index registers are hex (decimal) numbers, optionally preceded by R, between 1 and F (15). Register-memory instructions have the format rmop regnum,address{(index)} or rmop regnum,address{(index1,index2)} where the register number is a hex (decimal) number, optionally preceded by R, between 0 and F (15), the address is a hex number between 0 and 0xFFFF, and the index registers are hex (decimal) numbers, optionally preceded by R, between 1 and F (15). For memory operands, the simulator automatically chooses the format (RX1, RX2, RX3) that consumes the fewest bytes. If both RX1 and RX2 are feasible, the simulator chooses RX1.